Fully4world is a Platform for free learning about RAC and HVAC Fault Solutions, AC Error Codes, AC diagrams, Refrigerator diagrams, Compressor HP codes, HVAC jobs, AC Jobs, Refrigerator and AC jobs,
Refrigerator is useful Product for Every home And this product used in every home. Sometimes it contains an error code. We can fix some error codes at home and we need to call a technician to fix some error codes. In this post you will find all the error codes of AEG Refrigerator and I hope you will benefit a lot from this post. If you find it helpful, please share this post.
Error Codes
Solution
E0
No error
E1
Evaporator sensor damaged
E2
Room temperature sensor damaged (installed on the display board)
E4
Room temperature sensor damaged (installed on the power board)
E5
0 degree compartment sensor damaged
Er
http://IM/RAM Error. Check J4-4, J4-5 and J4-6 Connector on Icemaker board. Check J4 connector at Main Control board. Check 15 pin inline connector at control board, Pin#’s 4,9 & 14. If all connections test good, control board.
t3
TH3 Sensor (open or short) Go to flow chart for Ice t3
CE
IM Com Lost Go to flow chart 50C. Put into service mode to verify.
SY – EF
Evaporator Fan Failure
SY – CE
Communication Error
SY – CF
Communication Failure
F7
It might be that the power supply has been interrupted for a period or that the door has been too long or not properly closed.
F2
It is possibly a faulty thermostat.
Error Codes
Solution
E0
No error
E1
Evaporator sensor damaged
E2
Room temperature sensor damaged (installed on the display board)
E4
Room temperature sensor damaged (installed on the power board)
E5
0 degree compartment sensor damaged
Er
http://IM/RAM Error. Check J4-4, J4-5 and J4-6 Connector on Icemaker board. Check J4 connector at Main Control board. Check 15 pin inline connector at control board, Pin#’s 4,9 & 14. If all connections test good, control board.
t3
TH3 Sensor (open or short) Go to flow chart for Ice t3
CE
IM Com Lost Go to flow chart 50C. Put into service mode to verify.
SY – EF
Evaporator Fan Failure
SY – CE
Communication Error
SY – CF
Communication Failure
F7
It might be that the power supply has been interrupted for a period or that the door has been too long or not properly closed.
F2
It is possibly a faulty thermostat.
AEG Refrigerator Troubleshooting
Trouble
Possible Cause-Remedy
Appliance does not work.
Appliance is not switched on. Switch on the appliance.
Mains plug is not plugged in or is loose. Insert mains plug.Fuse has blown or is defective. Check fuse, replace if necessary.Fuse has blown or is defective. Check fuse, replace if necessary.
Fuse has blown or is defective. Check fuse, replace if necessary.
Socket is defective. Mains malfunctions are to be corrected by a qualified electrician.
The compressor runs continuously.
Temperature is set too cold. Set the Electronic Control to a warmer setting temporarily.
The food is too warm.
Temperature is not properly adjusted. Please look in the “Starting Up and Temperature Regulation” section.
Door was open for an extended period. Do not leave the door open any longer than necessary.
A large quantity of warm food was placed in the appliance within the last 24 hours. Set the Electronic Control to a colder setting temporarily.
The appliance is near a heat source. Please look in the“Installation location” section.
Interior lighting does not work.
Light bulb is defective. Please look in the “Changing the Light Bulb” section.
Heavy build up of frost, possibly also on the door seal.
Door seal is not airtight (possibly after reversing the door). Carefully warm the leaking sections of the door seal with a hair dryer (on a cool setting). At the sametime shape the warmed door seal by hand such that it sits correctly.
Unusual noises.
Appliance is not level. Readjust the feet.
The appliance is touching the wall or other objects. Move the appliances lightly.
The compressor does not start immediately after changing the temperature setting.
This is normal, no error has occurred. The compressor starts after a period of time.
Water in the bottom of the cabinet.
Water drain hole is blocked. See the “Cleaning and Care” section.
if you use a refrigerator, you must protect and care for your refrigerator so that your refrigerator performs well in cooling. The refrigerator should be placed in a place where there is ventilation (ventilation mean = Air Crossing). If you want to read more about AEG refrigerators, download the PDF file from the link below. You will find a lot Information in this PDF file.
This website uses cookies to improve your experience. We'll assume you're ok with this, but you can opt-out if you wish. Cookie settingsACCEPT
Privacy & Cookies Policy
Privacy Overview
This website uses cookies to improve your experience while you navigate through the website. Out of these cookies, the cookies that are categorized as necessary are stored on your browser as they are essential for the working of basic functionalities of the website. We also use third-party cookies that help us analyze and understand how you use this website. These cookies will be stored in your browser only with your consent. You also have the option to opt-out of these cookies. But opting out of some of these cookies may have an effect on your browsing experience.
Necessary cookies are absolutely essential for the website to function properly. This category only includes cookies that ensures basic functionalities and security features of the website. These cookies do not store any personal information.
Any cookies that may not be particularly necessary for the website to function and is used specifically to collect user personal data via analytics, ads, other embedded contents are termed as non-necessary cookies. It is mandatory to procure user consent prior to running these cookies on your website.