0

AEG Washing Machine Error Codes

Share
AEG Washing Machine Error Codes

AEG Washing Machine Error Codes

Washing Machine is useful Product from Every home And it is a product used in every home Sometimes it contains an error code. We can fix some error codes at home and we need to call a technician to fix some error codes. In this post you will find all the error codes of AEG washing machine and I hope you will benefit a lot from this post. If you find it helpful, please share this post.

Error CodeProblem
E10The appliance does not fill with water properly.
E11Poor fill before wash cycle. Tap off or water pressure too low; Drain hose improperly positioned; Fill valve is defective; Leaks on pressure switch; Pressure switch failed; Wiring fault; Main board defective. Cycle is paused with door locked Start
E12Difficulty in fill during drying (maximum time 3 min. fill in drying during the wash load phase) Tap off or water pressure too low; valve failed; pressure switch water circuit; pressure switches; wiring; main PCB. Cycle is paused
E13Water leaks. Drain hose improperly positioned; Water pressure too low; Fill valve is defective; Water circuit on pressure switch is leaking or blocked; Pressure switch faulty. Cycle is paused with door locked Start
E20The appliance does not drain the water
E21Poor draining. Drain hose kinked/clogged/improperly positioned; Drain filter clogged/dirty; Drain pump faulty; Pressure switch faulty; Wiring faulty; Main board faulty; Current leak between heating element and ground. Cycle is paused Start
E22Difficulty in fill during drying or drying condenser blocked (pressure switch closed on “FULL”) Drain hose kinked; filter blocked: drying condenser blocked; drain pump faulty; pressure switches faulty; wiring; main circuit board faulty; Current leakage between heater and ground. Cycle is paused Start
E23Defective triac for drain pump. Drain pump faulty; Wiring faulty; Main board faulty. Emergency drain procedure Cycle stops with door unlocked OFF/reset
E24Malfunction in sensing circuit on triac for drain pump. Main board faulty. Emergency drain procedure. Cycle stops with door unlocked OFF/reset
E31Malfunction in pressure switch circuit (frequency of signal from pressure switch out of limits) Pressure switch faulty; Wiring; Main PCB faulty; Cycle stops with door locked OFF/reset
E32Electronic pressure switch improperly calibrated (level on electronic pressure switch differs from 0-66 mm after initial calibration drain and when anti-boiling pressure switch is on “empty”). Tap is off or water pressure is too low; Fill valve faulty; Water circuit on pressure switches; pressure switches; Wiring; PCB faulty; Cycle is paused Start
E33Inconsistency between level on electronic pressure switch and level on anti-boiling pressure switch 1-2 (fault persists for at least 60 sec.). Pressure switch defective; Current leak between heating element and ground; Heating element; Wiring faulty; Main board faulty. Water circuit; Emergency drain procedure Cycle stops with door unlocked OFF/reset
E34Inconsistency between level on electronic pressure switch and level on anti-boiling pressure switch 2 (fault persists for at least 60 sec.). Pressure switch faulty; Electrical current leak between heating element and ground; Heating element faulty; Wiring faulty; Main board faulty. Water circuit; Emergency drain procedure Cycle stops with door unlocked OFF/reset
E35Overflow. Fill valve is faulty; Leaks from water circuit on pressure switch; Pressure switch defective; Wiring defective; Main board defective. Cycle stops. Emergency drain procedure. Drain pump continues to operate (5 min. on, then 5 min. off, etc.). OFF/reset
E36Sensing circuit on anti-boiling pressure switch 1 defective Main board faulty. Cycle stops with door locked OFF/reset
E37Sensing circuit on anti-boiling pressure switch 2 defective. Main board faulty. Cycle stops with door locked OFF/reset
E38Internal pressure takeoff is blocked (water level does not change for at least 30 sec. of drum rotation). Water circuit on pressure switches; Pressure switches; Motor belt broken; Heating phase is skipped
E39Defective HV sensing on anti-overflow system Main board faulty. Cycle stops with door locked OFF/reset
E40The appliance door is open or not closed correctly. Please check the door!
E3AFaulty sensing by heating resistance relay. Main board defective. Cycle stops with door locked OFF/reset
E41Door unlocked. Door lock faulty; Wiring faulty; Main board faulty. Cycle is paused Start
E42Problem closing the door. Door lock faulty; Wiring faulty; Main board faulty. Cycle is paused Start
E43Defective triac supplying power to door delay system. Door lock unit faulty; Wiring faulty; Main board faulty. (Emergency drain procedure) Cycle stops OFF/reset
E44Defective sensing by door delay system. Main board faulty. (Emergency drain procedure) Cycle stops OFF/reset
E45Defective sensing by triac on door delay system. Main board faulty. (Emergency drain procedure) Cycle stops OFF/reset
E51Motor power supply triac short-circuited. PCB faulty; current leakage from motor or from wiring loom. Cycle blocked, door locked (after 5 attempts) OFF/reset
E52No signal from motor tachometric generator. Motor faulty; wiring faulty; PCB faulty Cycle blocked, door locked (after 5 attempts) OFF/reset
E53Motor triac sensing circuit faulty. PCB faulty. Cycle blocked, door locked OFF/reset
E54Motor relay contacts sticking. PCB faulty; current leakage from motor or from wiring Cycle blocked, door locked (after 5 attempts) OFF/reset
E61Insufficient heating during washing. NTC sensor faulty; heating element faulty; wiring faulty; PCB faulty. The heating phase is skipped
E62Overheating during washing. NTC sensor faulty; heating element faulty; wiring faulty; PCB faulty. Safety drain cycle Cycle stopped with door open OFF/reset
E66Heating element power relay faulty. PCB faulty; current leakage from heating element to ground. Safety drain cycle Cycle stopped with door open OFF/reset
E71NTC sensor for wash cycle defective. Faulty NTC sensor; Wiring faulty; Main board faulty. Heating is skipped Start
E72Fault in NTC sensor on drying condenser (voltage out of range = short-circuit, open circuit) Drying NTC sensor (condenser) faulty; wiring faulty; main circuit board faulty. Heating is skipped Start
E73Fault in NTC sensor on drying duct (voltage out of range = short-circuit, open circuit) Drying NTC sensor (duct) faulty; wiring faulty; main circuit board faulty. Heating is skipped Start
E74NTC sensor for wash cycle improperly positioned. NTC sensor incorrectly positioned; Faulty NTC sensor; Wiring defective; Main board faulty. Heating is skipped Start
E82Error in selector reset position. PCB faulty (Wrong configuration data). Selector, wiring faulty OFF/reset
E83Error in reading selector. PCB faulty (Wrong configuration data). Selector, wiring Cycle cancelled
E84“Sensing” circuit on circulation pump triac faulty (input signal to processor always 0V or 5V) PCB Drain, cycle blocked (door open) OFF/reset
E85Circulation pump faulty (incongruency between status of “sensing” circuit on circulation pump and status of TRIAC) Circulation pump; wiring; main PCB Drain, cycle blocked (door open) OFF/reset
E91Communication incongruence between main PCB- display board (versions not compatible) Wiring faulty; Faulty control/display board Main PCB faulty. Cycle interrupted
E92Communication incongruence between main PCB- display board (versions not compatible) Wrong control/display board; Wrong PCB (do not correspond to the model). Cycle interrupted
E93Incorrect configuration of appliance. Incorrect configuration data; PCB faulty. Cycle interrupted OFF/reset
E94Incorrect configuration of washing cycle. Incorrect configuration data; PCB faulty. Cycle interrupted OFF/reset
E95Communication error between microprocessor and EEPROM PCB faulty. Cycle interrupted OFF/reset
E97Incongruence between programme selector and cycle configuration. Faulty PCB (Wrong configuration data). Cycle interrupted OFF/reset
EB1Frequency of appliance incorrect. Power supply problems (incorrect / disturbance); PCB faulty. Cycle interrupted
EB2Voltage too high. Power supply problems (incorrect / disturbance); PCB faulty. Cycle interrupted
EB3Voltage too low. Power supply problems (incorrect / disturbance); PCB faulty. Cycle interrupted
EC1Solenoid valve inoperative but flow meter operating. Main board faulty, Fill valve faulty Cycle stops with door locked (after 5 attempts). OFF/reset
EC2Signal from turbidity sensor out of limits. Turbidity sensor faulty, Main board faulty, Wiring faulty Start/reset
EC3Signal from weight sensor out of limits. Weight sensor faulty, Main board faulty, Wiring faulty Start/reset
EF0The anti-flood device is on. Disconnect the appliance and close the water tap. Contact the Authorised Service Centre.
EF1Drain filter blocked (too long drain phase) Drain tube blocked/kinked/too high; Drain filter dirty/blocked. Warning displayed at the end of cycle (specific LED)
EF2Overdosing of detergent (too much foam during drain phases) Excessive detergent dosing; drain tube kinked/blocked; Drain filter dirty/blocked.
EF3Control water intervention. Water leakage on the base; faulty water control device. Water drain and cycle blocked OFF/reset
EF4Low pressure of water fill, no signal of flow meter and solenoid open Tap closed, low water fill pressure … Reset
E00No alarm
EH0The mains supply is unstable. Wait until the mains supply is stable.

AEG LAVAMAT Washing Machine Error Codes

Error Code Problem
C1Not filling/ too slow fill
C2Not pumping/too slow pump output
C3Aqua control activated
C7Not heating
C8NTC fault
C9Tacho or motor fault
CAMotor triac short circuit
CDDoor lock faulty
CEWater distributor fault, this machine has a small motor in the dispenser to select the Compartment to fill through, this in turn operates a micro switch inside the dispenser.
CFEPROM fault Some of these faults are locked in and will return even if machine is disconnected; the only way to clear them is to run the test programme. Hold in Pre wash and soak button while turning rotary knob to gentle spin.

LAVAMAT 8 Series Error Codes

Error CodeProblem
COlmbalance between both Pressure Switches, Heater or wiring fault.
C1No water in, valve at fault or low pressure.
C2Pump blockage, pump open circuit, drain blockage.
C3Safety flood device operated, pump fault, module fault.
C4Pump fault.
C5Overheat sensor on main motor.
C6Pressure switch fault.
C7Heater or heater relay fault.
C8NTC fault.
C9Tacho fault.
CAMOS-FET transitor defective.(Replace main module)
CBOverfill/level fault or inlet valve.
CCPTC for MOS-FET transistor fault, main motor fault.
CDDoor Interlock fault.
CFChecksum EEPROM fault, configuration error on module.

AEG Washing Machines – Washer-Dryers Alarm Codes and Solutions

Alarm CodeSolution
E11Difficulties in water fill for washing. Tap closed or water pressure too low; Drain tube improperly positioned; Water fill solenoid valve is faulty; Leaks from water circuit on pressure switch; Pressure switch faulty; Wiring faulty; PCB faulty.
E12Difficulties in water fill for drying. Tap closed or water pressure too low; Drain tube improperly positioned; Water fill solenoid valve is faulty; Leaks from water circuit on pressure switch; Pressure switch faulty; Wiring faulty; PCB faulty.
E13Water leakage. Drain hose incorrectly positioned; mains pressure insufficient; water fill solenoid faulty; leakage/blockage of pressure switch hydraulic circuit; pressure switch faulty.
E21Difficulties in draining for washing. Drain tube kinked/clogged/improperly positioned; Drain filter clogged/dirty; Drain pump faulty; Pressure switch faulty; Wiring faulty; PCB faulty.
E22Difficulties in draining for drying. Drain tube kinked/clogged/improperly positioned; Drain filter clogged/dirty; Drain pump faulty; Pressure switch faulty; Wiring faulty; PCB faulty.
E23Drain pump triac faulty. Drain pump faulty; Wiring faulty; PCB faulty.
E24Fault in “sensing” circuit of drain pump triac (wrong input signal to microprocessor) PCB faulty.
E31Electronic pressure switch circuit faulty (frequency of pressure switch signal out of limits) Electronic pressure switch; Wiring; PCB faulty.
E32Incorrect calibration of electronic pressure switch (The electronic pressure switch generates a signal with instable frequency during the drain phase). Drain tube kinked/clogged/improperly positioned; Drain filter clogged/dirty; Drain pump faulty; Leaks from water circuit on pressure switch; Pressure switch; Wiring faulty; PCB faulty.
E35Water overflow. Water fill solenoid faulty; Leaks from water circuit on pressure switch; pressure switch faulty; wiring faulty; PCB faulty.
E38Pressure chamber blocked (water level does not vary for at least 30 sec. during drum rotation) Motor drive belt broken; Hydraulic circuit pressure switch clogged.
E3AHeating elem. relay sensing faulty (input signal to microprocessor always 0V or 5V) PCB faulty.
E41Door open (after 15 sec.) Door interlock faulty; wiring faulty; PCB faulty.
E42Problems of door closure. Door interlock faulty; wiring faulty; PCB faulty.
E43Interlock power supply triac faulty. Door interlock faulty; wiring faulty; PCB faulty.
E44Door interlock sensing circuit triac faulty. PCB faulty.
E45Door interlock sensing circuit triac faulty (wrong input signal to microprocessor) PCB faulty.
E52No signal from motor tachometric generator. Motor faulty; wiring faulty; PCB faulty.
E57Inverter is drawing too much current (>15A). Motor-Inverter wiring faulty; Inverter board faulty, Motor faulty.
E58Inverter is drawing too much current (>4,5A). Motor abnormal operation (overloaded); Motor-Inverter wiring faulty; Motor faulty; Inverter board faulty.
E59No signal from tachometric generator for three seconds. Motor-Inverter wiring faulty; Inverter board faulty, Motor faulty.
E5AOverheating for heat dissipator for Inverter. Overheating caused by continuous operation or ambient conditions (let appliance cool down); Inverter board faulty. NTC open (on the Inverter board).
E5HInput voltage is lower than 175V. Wiring faulty; Inverter board faulty
E5CInput voltage is too high. Input voltage is too high (measure the masters voltage); Inverter board faulty.
E5dData transfer error between Inverter and main board. Line interference; Wiring faulty; Main board or Inverter faulty.
E5EWrong communication between main board and Inverter. Main board-Inverter wiring faulty; Inverter board faulty; Main board faulty.
E5FInverter board does not start the motor. Wiring faulty; Inverter board faulty; Main board faulty.
E61Insufficient heating during washing. NTC sensor faulty; heating element faulty; wiring faulty; PCB faulty.
E62Overheating during washing (temperature higher than 88°C for a time higher than 5 min.) NTC sensor faulty; heating element faulty; wiring faulty; PCB faulty.
E66Heating element power relay faulty (incongruence between sensing and relay) PCB faulty.
E68Current dispersion to earth (value of mains voltage different from main value) Current dispersion between between heating element and earth.
E69Heating element interrupted. Wiring faulty; Heating element for washing interrupted (thermofuse open)
E71Washing NTC sensor faulty (short- circuited or open) Wiring faulty; Washing NTC sensor faulty; PCB faulty.
E72Drying condenser NTC sensor faulty (voltage value out of limits, sensor short-circuited or open) Wiring faulty; Drying NTC sensor (condenser) badly positioned or faulty; WD board faulty.
E73Drying duct NTC sensor faulty (voltage value out of limits, sensor short-circuited or open) Wiring faulty; Drying NTC sensor (duct) badly positioned or faulty; WD board faulty.
E74Washing NTC sensor badly positioned. Wiring faulty; Washing NTC sensor badly positioned; NTC sensor faulty; PCB faulty.
E82Error in selector reset position. PCB faulty (Wrong configuration data).
E83Error in selector reading. PCB faulty (Wrong configuration data.
E91Communication error between PCB and display board. Wiring faulty; Control/display board faulty: PCB faulty.
E92Communication incongruence between main PCB- display board (versions not compatible) Wrong control/display board; Wrong PCB (do not correspond to the model).
E93Incorrect configuration of appliance. PCB faulty; (Incorrect configuration data).
E94Incorrect configuration of washing cycle. PCB faulty; (Incorrect configuration data).
E95Communication error between microprocessor and EEPROM. PCB faulty
E97Incongruence between programme selector and cycle configuration. Faulty PCB (Wrong configuration data).
E98Communication error between main board – Inverter. Incompatibility between main board and Inverter.
E9HCommunication error between microprocessor and FLASH memory. Display board.
E9CMachine configuration error. Display board.
E9dClock faulty. Display board.
E9FCommunication error between PCB and remote devices. Wiring between PCB and Inverter faulty; PCB faulty; Inverter faulty.
EA1Drum positioning (DSP) faulty. Motor belt broken; Wiring faulty; PCB faulty; DSP sensor faulty.
EA6DSP door opening faulty. Motor belt broken; Wiring faulty; Drum cover open. Motor faulty; PCB faulty.
EC1Solenoid valve blocked with flowmeter working. Wiring faulty; Solenoid valve faulty/blocked, PCB faulty.
EC3Problems with Weight sensor (no signal or out of limits) Wiring faulty; Weight sensor faulty; PCB faulty.
Ed1Data communication error between WD board and PCB. Wiring faulty between PCB and WD board; WD board faulty; PCB faulty.
Ed2Drying heating element relay 1 faulty. Wiring faulty between WD board and thermostats; thermostats faulty; WD board faulty, PCB faulty.
Ed3Drying heating element relay 2 faulty. Wiring faulty between WD board and thermostats; thermostats faulty; WD board faulty, PCB faulty.
Ed4Relay which commutates power between washing heating element and drying (in the WD board). Wiring faulty; WD board faulty; PCB faulty.
Ed6No communication between PCB and display board (INPUT). Wiring faulty between PCB and programme display board; PCB faulty.
EF1Drain filter blocked (drain phase too long) Drain tube blocked/kinked/too high; Drain filter dirty/blocked.
EF2Excessive detergent dosing (excessive foam during draining) Excessive detergent dosing; drain tube kinked/blocked; Drain filter dirty/blocked.
EF3Aqua control intervention. Water leaks onto base frame; water control system defective.
EF4Water fill pressure low, no signal of flowmeter and solenoid valve open. Tap closed; water fill pressure low.
EF5Unbalanced load. Final spin phases skipped.
EF6Reset. No action to be performed, if continues replace the PCB.
EH1Frequency power of appliance out of limits. Power supply problems (incorrect / disturbance); PCB faulty.
EH2Voltage too high. Power supply problems (incorrect / disturbance); PCB faulty.
EH3Voltage too low. Power supply problems (incorrect / disturbance); PCB faulty.
EHFSafety “sensing” circuit faulty (input voltage to microprocessor wrong) PCB faulty.
EHEIncongruence between safety relay (in the PCB) and the safety “sensing” circuit. Wiring faulty; PCB faulty.