Tag: ac repairac installation

Why Comes Ice on Evaporator and how this solve Fault

Why Comes Ice on Evaporator and how this solve Fault Sometimes Ice comes on evaporator of Window AC when Ice comes on windows AC then AC cooling doesn’t do well. There are many reasons why ice can come to Evaporator. One of which is this. Window AC have one Fan which work for Evaporator and

Indoor and Outdoor both Not Turn ON Solve faults |Fully4world

Indoor and Outdoor both Not Turn ON Solve faults Sometimes your indoor and outdoor both are not work but main power is ON. when we face this problem then we should check Transformer of his PCB kit If his Transformer is OK then check his Fuse. Mostly comes faults when indoor and outdoor unit not

Mostly Faults Comes in Indoor Unit | Fully4world

Mostly Faults Comes in Indoor Unit We face some faults mostly in Indoor unit. we can easily solve this faults. Ice on Evaporator : if we see Ice on Evaporator then we should service AC . If AC is already serviced then check his blower motor speed if his speed is low then we show

AC Compressor wiring burn and installed new wires

AC Compressor wiring burn and installed new wires Sometimes our AC’s every thing ON but do not Cooling Outdoor fan running but Outdoor compressor not running sometimes our compressor burn but sometimes our Compressor wiring burn And the compressor survives. in this Condition that our wiring burn we should take off the old wires new

Indoor air throw low Reasons and Solve Problems

Indoor air throw low Reasons and Solve Problems If our AC’s indoor air throw is low Then the ice comes on the suction pipe. Indoor air throw low have many reasons.  If our AC need Service (Evaporator is dirty) If Blower is dirty If Blower motor is damaged If Blower motor capacitor is damaged Air

Gas Store, R600, Long Pipe, Question and Answer ?

Q1. How much is R600 Gas Running Pressure and Standing Pressure? Ans. R600 Running  Pressure is 0 Psi to 2 Psi and Standing Pressure is 40 Psi to 50 Psi. Q2. What we can Attach 2 Ton indoor Unit with 1.5 Ton Outdoor unit ? Ans. Yes we can Attach 2 Ton indoor with 1.5

R32 Use and Risk|FAQ’s R32 by Toshiba

FAQ’s R32 Why is R32 Required? The Main Pillars of the new EU F-Gas Rules are to reduce emissions and to move towards lower GWP solutions. This involves a phase down in the consumption of HFCs and a reduction of 37% by 2020 and 79% by 2030. By 2025 Single Split A/C systems with less

How to open easy rust screws & Bolts

Open rust able screws & Bolts Sometimes rust gets on our nut or Screw, and it doesn’t open easily, screw driver and key are happening slipped. we can open it with some ways. By heating it By using WD40 By grip plier By Heating : we can heat it by gas welding plant but be