In this post Changhong Ruba DC inverter Error Code List available Read and Fix Problems.
Error | Description |
---|---|
F1 | Indoor Room Temperature Sensor Fault |
F2 | Outdoor Discharge Temperature Sensor Fault |
Over current Protection | |
F3 | Indoor Coil Temperature Sensor Fault |
F4 | Indoor Fan Motor Faukt |
F4 | Outdoor Section Line Temperature Sensor Fault |
F5 | Gas Pressure High or Low |
4 way valve abnormal | |
F6 | Communication Fault Between indoor to Outdoor |
F7 | Frequency Mismatch |
Phase Sequence | |
F7/F8 | Communication Between Indoor to Outdoor |
R0/R1 | AC Voltage High or Low |
Compressor Error | |
Overheat protection for Exhaust Temp | |
E0 | Over Current Protection for Single Compressor |
Middle part of condenser Temp sensor fail | |
E1 | Communication error between indoor control board & Indoor PCB |
E2 | Outdoor fan motor fault |
Frost removing temp sensor failure | |
Section temp sensor failure | |
Outdoor Ambient temp sensor failure | |
Exhaust temp sensor failure | |
Devite from normal for the compressor | |
Loop of the station detect error | |
Overcurrent of the compressor | |
C1 | Outdoor EEPROM error |
Indoor EEPROM error | |
P5 | Anti Freezing Protection |
Error Code of Changhong Ruba Inverter AC
SR NO # | ODU Light Flash | IDU Display | Fault Details |
---|---|---|---|
1 | 1 | EF | Outdoor Unit EEPROM fault |
2 | 2 | F6 | Indoor and Outdoor Communication fault |
3 | 3 | F8 | Main Board and Driver Board Communication fault |
4 | 4 | E4 | Compressor Starting abnormal (phase failure, reverse) |
5 | 5 | E3 | Compressor out-of-step-fault |
6 | 6 | F9 | IPM module fault |
7 | 7 | E0 | Compressor shell roof fault/protection |
8 | 8 | F5 | Exhaust Temperature sensor fault |
9 | 9 | E5 | Suction Temperature sensor fault |
10 | 10 | F4 | Outdoor Coil Temperature sensor fault |
11 | 11 | F2 | Outdoor ambient Temperature sensor |
12 | 12 | E2 | Outdoor DC fan motor fault |
13 | 13 | P2 | Outdoor AC current protecion |
14 | 14 | P0 | Compressor phase current protecion |
15 | 15 | P7 | Outdoor unit Over-high/Over-low AC Voltage Protection |
16 | 16 | P8 | Outdoor unit Over-high/Over-low DC Voltage Protection |
17 | 17 | P9 | IPM over-high temperature protection |
18 | 18 | P1 | Exhaust temperature overheat protection |
19 | 19 | P5 | Cooling indoor coil anti freezing protection |
20 | 20 | P6 | Cooling outdoor coil overheat protection shutdown |
21 | 21 | P4 | heating indoor coil overheat protection |
22 | 22 | PA | Cooling outdoor ambient temperature over-low protection |
23 | 23 | PE | Heating outdoor ambient temperature over-High protection |
24 | 25 | EE | Indoor Unit EEPROM fault |
25 | 26 | F0 | Indoor fan motor fault |
26 | 27 | E1 | Indoor PCB zero crossing fault |
27 | 28 | F3 | Indoor coil fault and sensor fault |
28 | 29 | F1 | Indoor room temperature sensor fault |
29 | / | E8 | Outdoor system exception |
30 | / | P3 | Heating and Removing cream tips |
Ryt
P1 p2 p3p4p5p6p7p8 ke bare me batao
Inverter a.c. or pcs board banane ke bare me gaed line fe
Hi, My outdoor unit fan not working properly and showing error FI,
Kindly request you that provide me solution about F1 error.
Thanks.
Hi,
Please note my split AC is Changhong Ruba against outdoor unit fan not working proper and showing error FI,
Kindly provide solution.
Thanks.
https://www.fully4world.com/changhong-ruba-dc-inverter-error-code/
How about error f9 mean at changhong inverter? Need explain to fix it. Thanks
chang ruba error show display roll icon and cooling 25% fan speed to low please help
Right ji
Sir I have kenwood envie ac unit and found f6 error, can you help and guide me in this regard.
Jazaak Allah
chang ruba Dc inverter 1.5 ton ac showing error r0.
There is no voltage problem , i checked it.
Chang Ruba Dc Invartar 1.5 Ton Ac Showing Error r0 .. kia problem ho sakti ha voltage 245v
Voltas 2ton inverte ac error code’HC’
PLEASE GUIDE for this
Thanks
Chang hang ruba inverter ac 1.5 F7 error code aa jata ha. Plz help
Showing F7 error
Changhong 1.5 inverter ac
Plz guide
Yhan kisi ko smhj nahi aa rahi
Hi All,
Changhong ruba 1.5 inverter AC shows R0 error with blinking LCD. What is the possible cause? Please help.
Salam,
Kisi bhai k pass error r0 ka solution hai bohat se dosto ny ye error mention bhi kiya hai voltage bhi power hotey hai jab error ata hai kya kisi ko is ka solution mila plz guide
What is J0 error kindly tell
https://www.fully4world.com/ac-error-code-app/
chang ruba 1.5 ton pa r0 error ata ha voltages stable han
Kindly suggest the solution and reason for RO error with screen also blinking, When this error appears screen starts blinking and AC stops cooling. But when you restart the AC it starts cooling again.
r0 error plz any solution changhon ruba