Tag: Air conditioner error code list download and rectifier error problem

Shell and Tube Type Condenser Diagrams

In English Shell and Tube Type Condenser Use in Big Units. In the small AC Like 2 Ton , 4 Ton we use Fan in Outdoor To keep the condenser cool But shell and Tube type Condenser we use Water To keep the condenser cool. In Urdu / Hindi Shell and Tube type condenser bary

Mostly Coming Error code in Air Conditioner

Coming Error code in Air Conditioner Error Code List : E1 Compressor High pressure Protection E2 Indoor anti-freeze Protection E3 Compressor Low pressure Protection , Refrigerant lack Protection and refrigerant collating mode E4 Compressor High discharge temperature Protection E6 Communication error E8 Indoor fan motor error E9 Full water protection HVAC and RAC Learn platform

Mostly Faults Comes in Indoor Unit | Fully4world

Mostly Faults Comes in Indoor Unit We face some faults mostly in Indoor unit. we can easily solve this faults. Ice on Evaporator : if we see Ice on Evaporator then we should service AC . If AC is already serviced then check his blower motor speed if his speed is low then we show

Indoor air throw low Reasons and Solve Problems

Indoor air throw low Reasons and Solve Problems If our AC’s indoor air throw is low Then the ice comes on the suction pipe. Indoor air throw low have many reasons.  If our AC need Service (Evaporator is dirty) If Blower is dirty If Blower motor is damaged If Blower motor capacitor is damaged Air

E4, E5, E6 Error Code in non Inverter AC Solve

E4, E5, E6 Error Code in non Inverter AC Solve Some Non Inverter AC don’t  show error Code but some show error in LED. When we see E4 error in non Inverter then we should check his indoor Blower Motor we should disconnect wire his blower motor from PCB and again Connect and check that

Light blink error Solve problem|Error code

Light blink error Old model of AC light blink error, indoor unit is ON but power supply not reach outdoor. When we see this error then we should change his room temperature and coil sensor if his sensor is OK then remove his sensor Jack and re apply if not solve this problem then his

Crrier DC inverter Error Code list

The error message is shown at the OUTDOOR UNIT CONTROLLER as following table: Outdoor Temperature Sensor Failure Ambient temperature sensor E0 Inlet coil temperature sensor E1 Suction temperature sensor E2 Mid coil temperature sensor E3 DLT Digital Compressor sensor E4 Outdoor Status Error Communication error between indoor & outdoor unit controllers [E High pressure status

Galanz AC Error Code

F6 PG motor faults F7 Indoor TEMP sensor faults F8 Indoor coil pipe TEMP sensor faults F9 Outdoor coil pipe TEMP sensor faults Trouble Solve Methods E1 The trouble of indoor unit room temperature sensor. E2 The trouble of unit pipe temperature sensor. indoor E3 The trouble of PG motor E5 The trouble of bad

Acson AC Error Codes and Troubleshooting

The code indication changes as shown below, and notifies with a long beep. E1 Outdoor Pcb Error E3 High Pressure Protection E4 Low Pressure Protection E5 Compressor Motor Lock/Compressor Overloaded E6 Compressor Start-up Error E7 Outdoor Dc Fan Motor Lock E8 Ac Input Over Current E9 Exv Errorea 4 Way Valve Error F3 Discharge Pipe

Carrier Indoor Unit Error Code

E0 Indoor unit EEPROM parameter error E1 Indoor / outdoor units communication error E3 Indoor fan speed has been out of control E4 Indoor room temperature sensor T1 open circuit or shortcircuit E5 Evaporator coil temperature sensor T2 open circuit or short circuit EC Refrigerant Leakage Detection F1 Outdoor ambient temperature sensor T4 open circuit