Split AC Outdoor wiring Diagram

In this post you can see Normal Split AC Outdoor wiring Diagram. You can easily do after see wiring. this is simple wiring of outdoor. Diagram You should read it : Haier Indoor PCB Wiring Diagram Kenwood 2 Cabinet AC Indoor Wiring 4 Ton 3 Phase indoor Wiring Diagram Gree GS-12UG3S Indoor Wiring Diagram (1

Outdoor Fan Speed Slow Problems and Faults |F4W

Outdoor Fan Speed Slow Problems and Faults If your AC’s Outdoor Fan Speed is low then we can see many problems and  fault. If you outdoor fan speed is low then compressor will Heat up and the compressor will trip. Compressor will take more ampere when compressor will heat up. After this Your Compressor capacitor

AC Compressor wiring burn and installed new wires

AC Compressor wiring burn and installed new wires Sometimes our AC’s every thing ON but do not Cooling Outdoor fan running but Outdoor compressor not running sometimes our compressor burn but sometimes our Compressor wiring burn And the compressor survives. in this Condition that our wiring burn we should take off the old wires new

Indoor air throw low Reasons and Solve Problems

Indoor air throw low Reasons and Solve Problems If our AC’s indoor air throw is low Then the ice comes on the suction pipe. Indoor air throw low have many reasons.  If our AC need Service (Evaporator is dirty) If Blower is dirty If Blower motor is damaged If Blower motor capacitor is damaged Air

How to Uninstall Split AC (Air Conditioner)

How to Uninstall Split AC (Air Conditioner) Before uninstall any Split Air Conditioner we should Store his Gas. Tools we need for Uninstall Air Conditioner: L Key 4mm or 5mm , 2 Screw Wrench, Screw Driver, Plier Turn On AC and set Temperature at 18°C  When Turn on the Outdoor we should Close his Discharge

Outdoor Fan Motor 4 Wires Connection and Trace

Outdoor Fan Motor 4 Wires Connection and Trace If outdoor fan motor have 4 wire then how we can trace that which is common running starting which is 4th wire. we can easily find with multi-meter, multi-meter set on Continuity (Beep) and in this 4 wires 2 wires work same this 2 wires attach with

Window AC ICE on Pipe Solve Fault

Window AC ICE on Pipe If ice coming on your Windows AC Piping. Turn your AC on and You should check your running gas pressure with line Gauge. R22 refrigerant Running back pressure is 65 PSI. If your Gas is low you should charge your Gas and if your Gas is high you should reduce your

Split AC Outdoor Gas Valves Changing | in English

Split AC Outdoor Gas Valves Sometimes the gas valves are leaked. When gas valves are damaged. They are gas valves. From where we close the gas and open with L key. When gas valves are damaged. We Should change Gas valves. Sometimes We checked all the gas leak point but We not check gas valves.