Dc inverter error codes F1.F2.F4 | Fully4world

Tag: Dc inverter error codes F1.F2.F4

Light blink error Solve problem|Error code

Light blink error Old model of AC light blink error, indoor unit is ON but power supply not reach outdoor. When we see this error then we should change his room temperature and coil sensor if his sensor is OK then remove his sensor Jack and re apply if not solve this problem then his

Samsung 1.5 Ton Heat & Cool Air Conditioner buy online

Features : Full HD Filter Auto Clean Dehumidification Low Watt Turbo Cooling Triple Protector Anti-bacteria coating Model Samsung AR18NSFPFWK2PM Fast Cool Yes Auto Clean (Self Cleaning) Yes Refrigerant (Type) R410A Operating Current(Heating, A) 8.0 A Operating Current(Cooling, A) 7.0 A Power Source(Φ/V/Hz) 1, 220~240~, 50 You should read it : How to Service window AC

Outdoor Fan Motor 4 Wires Connection and Trace

Outdoor Fan Motor 4 Wires Connection and Trace If outdoor fan motor have 4 wire then how we can trace that which is common running starting which is 4th wire. we can easily find with multi-meter, multi-meter set on Continuity (Beep) and in this 4 wires 2 wires work same this 2 wires attach with

How Check Rotary Compressor is damage or not

How Check Rotary Compressor is damage or not we can also check with Multi meter that our Compressor is damage or not. we should always check his terminal continuity value. How to check common Running Starting If any point not show continuity value on meter then compressor is damage. if Compressor running with high ampere

PEL ACE Air Conditioner 1.5 Ton Price & Spec| Buy Online

Features : This advanced technology feature guarantees optimum performance and high energy savings. It starts the Air Conditioner even on 140 Volts that gives excellent energy saving experience. PEL Air Conditioners are built to work on maximum efficiency that not only saves energy but also gives annual savings. Full capacity units with full wattage compressor

AC Compressor Triping top Reason | Outdoor Triping

Compressor Triping top Reason Mostly Outdoor Units trip Due to heat up, we do Discuss some top reason of Outdoor Compressor Triping. If our Coil sensor is damage then this problem comes in PCB that our sensor is damage, But by this problem our all Outdoor closes, his fan and his Compressor. If our Compressor

Crrier DC inverter Error Code list

The error message is shown at the OUTDOOR UNIT CONTROLLER as following table: Outdoor Temperature Sensor Failure Ambient temperature sensor E0 Inlet coil temperature sensor E1 Suction temperature sensor E2 Mid coil temperature sensor E3 DLT Digital Compressor sensor E4 Outdoor Status Error Communication error between indoor & outdoor unit controllers [E High pressure status

Galanz AC Error Code

F6 PG motor faults F7 Indoor TEMP sensor faults F8 Indoor coil pipe TEMP sensor faults F9 Outdoor coil pipe TEMP sensor faults Trouble Solve Methods E1 The trouble of indoor unit room temperature sensor. E2 The trouble of unit pipe temperature sensor. indoor E3 The trouble of PG motor E5 The trouble of bad

Acson AC Error Codes and Troubleshooting

The code indication changes as shown below, and notifies with a long beep. E1 Outdoor Pcb Error E3 High Pressure Protection E4 Low Pressure Protection E5 Compressor Motor Lock/Compressor Overloaded E6 Compressor Start-up Error E7 Outdoor Dc Fan Motor Lock E8 Ac Input Over Current E9 Exv Errorea 4 Way Valve Error F3 Discharge Pipe

DC Inverter E1 Error Solved [In Hindi/Urdu and English]

In Urdu In English We found E1 Error Orient DC Inverter. The E1 Error is an Out Door Temperature  sensor or indoor Temperature sensor. And then i Changed Both Sensors But after all this change, the problem was not resolved. when i open the PCB kit from Out Door,  Then I see that the part