0

Smeg Washing Machine Error Codes

Smeg Washing Machine Error Codes

Smeg Washing Machine Error Codes

Washing Machine is useful Product from Every home And it is a product used in every home Sometimes it contains an error code. We can fix some error codes at home and we need to call a technician to fix some error codes. In this post you will find all the error codes of Smeg washing machine and I hope you will benefit a lot from this post. If you find it helpful, please share this post.

Error CodesSolutions
OPENDoor not properly closed. Try reclosing.
E1Aqua stop device tripped. Cut off power supply, turn off water tap and contact nearest service centre.
E2Anti-spilling device (only outside washing program)
E4NTC water in short circuit or interrupted.
E5Water not taken in for washing. See point 2 in troubleshooting table.
E6Water not pumped out. See point 4 in troubleshooting table.
E10Motor over current.
E11Motor control triac in short circuit or interrupted.
E12Tachometer.
E13PTC door block.
E14NTC dryer in short circuit or interrupted..
Failure 2Washing program does not start. FAILURE 2. Door is not properly closed. Push it towards the machine.
Failure 3Water does not enter the machine. FAILURE 3. Disturbed water inlet. Check if: the water faucet is open, inlet pipe net filter is clean. (Push the START button again).
Failure 7Water is poorly pumped out or not at all (machine signals FAILURE 7). Water outlet is clogged. Check if: the filter is clean, outlet pipe is not jammed, outlet pipe is positioned higher than 1 m. (Push START knob again).
AF:01Water not heated within time allowed. Cycle in progress, heating phases.
AF:02The temperature difference between the two probes, “TL1” and “TC”, is more than 2°C (only active on WD series)
AF:04Probe “TL1” (chamber temperature ) shows a reading higher than the actual temperature.
AF:05Working temperature probe “TL1” is generating an abnormal signal (probe “open”).
AF:07Drying temperature probe TA1 is generating an abnormal signal (probe “open”).
AF:10Control temperature probe TCL is generating an abnormal signal (probe “open”). (only active on WD series)
AF:11No cold water during filling.
AF:13No demineralis ed water.
AF:17Cold water filling time not correct.
AF:19Demi filling time too long. The device is taking too long to take in demineralis ed water.
AF:23Not enough water. Chamber water level too low.
AF:25Malfunction related to washing pump “ML”. Washing pump pressure too low.
AF:26Malfunction involving water being taken into chamber at wrong time. Cold water intake valve “EVF” may have failed.
AF:28Malfunction involving demineralis ed water being taken into tank at wrong time. Cold water intake valve “EVF” may have failed.
AF:29Chamber does not empty. Pump-out not occurring.
AF:30During the working cycle, the chamber water level exceeds the safety level. Water safety level.
AF:32Water standing in washing chamber with device in standby.
AF:33Steam condenser water intake anomaly. No water in steam condenser.
AF:34Steam condenser water drainage failure.
AF:37Drainage problems when using a mixture of water.
A:41P1 detergent intake anomaly
A:42P2 detergent intake anomaly
A:43P3 detergent intake anomaly. Equivalent to A 41 but for P3.
AF:54Door opening detected with cycle in progress. Door interlock microswitch malfunction.
AF:56Door interlock device malfunction, automatic opening failure.
AF:58Dryer heating failure.
AF:67Dryer motor “cooling” malfunction. Cooling is included at the end of the drying phase to bring the load processed and the heating elements to a safe temperature
A:68P1 jerry can empty
A:69P2 jerry can empty
A:70P3 jerry can empty
AF:73Internal memory data storage error
AF:74Water leak from chamber. Alarm only enabled with the Acquastop accessory fitted.
AF:75No salt in softener. This alarm does not appear on the Display but is recorded in the appliance memory; the relative LED illuminates on the display.
AF:77Intake water temperature over 45°C; prewash temperature must be below 45°C. Alarm generally disabled on GW series products.
AF:78Restore fail. Motherboar d problem. Status reset error. Date not saved correctly the last time the device was switched off.
AF:79Program not compatible. Check performed at start-up: program setting error. The program cannot be run (e.g. because recycled water or an alternative drain is not available)
AF:84Dryer temperature reading higher than actual temperature
AF:91Internal memory full. No response. If the setup overwrite function is not set as on, the device shuts out; it does not perform any further cycles until the memory is cleared. Download and clear the memory following the procedure described in the WD-TRACE manual.
AF:92Drying filter maintenance. Replace the drying absolute filter and reset the counter. Also decide whether to replace the relative filter.
AF:93Device maintenance. Service the device and inspect all parts potentially subject to wear. Decide whether to make any replacements.
AF:94Temperatur e below target temperature during extension phase. T not stable.
AF:96Analog pressure switch malfunction.

Smeg Washing Machine Troubleshooting

TroublePossible Cause-Remedy
The machine does not work (display is not illuminated).Machine is not powered. Check if: plug is in the socket, there is power in the socket, the fuse is OK.
Water does not enter the machine.Filter is not tightly screwed in. Inlet pipe is not tightly screwed to the machine or to the water faucet. Outlet pipe fell to the floor. Tighten the filter properly. Tighten the inlet pipe. Affix the outlet pipe to the drain.
The machine moves during operation.The machine is not properly leveled. Transport brackets are not removed. Level the machine with the adjustable legs. Remove transport brackets.
The machine vibrates during the spin.Unevenly distributed laundry, especially with very small quantities (for ex. only the bathrobe). This is normal, the machine will reduce the RPM if vibrations are too strong. Wash larger quantity of laundry.
Excessive foaming during washing.Excessive measure of detergent. Use washing powder according to the instructions by the producer and according to the water hardness and soiled laundry. Use only detergents for machine washing.
Laundry is not properly spun. No failure is reported.The machine switched on the UKS* function. Because of bad laundry balance, the machine has automatically reduced spin RPM. The machine operates normally. Wash large and small pieces of laundry together.
Greasy wads appear on the laundry.Too little detergent (laundry was very greasy). Wash the laundry again. Add more detergent for such soiled laundry, or use liquid detergent.
Laundry is stained after washing.You used liquid detergent or detergent for colored laundry which does not contain whitener. You selected inappropriate program. Use the detergent containing whitener. Select the heavily soiled laundry program, or activate soaking function.
White powdery residues on the laundry.It is not the consequence of bad rinsing, but because of neo-phosphate detergents containing non soluble components (zeolites) for water softening. Such substances may be deposited upon the laundry. Inappropriately selected program. Immediately rinse the laundry once again. Use liquid detergents which do not contain zeolites. Try removing the residues with the brush. Use program for heavily soiled laundry, or activate soaking function.
Detergent residues in the dispenser.Low water flow pressure. Some detergents may stick to the dispenser rather hard if it is wet. Clean the inlet pipe screen. Wipe the dispenser prior loading detergent.
Softener is not completely rinsed, or water is left in the dispenser dish.Sucking cover is not correctly positioned or is clogged. Clean the dispenser and firmly fix the cover to its place.
Washing time is longer than usual.The machine switched on the UKS* system because of uneven laundry load. Power failure occurred. Clean water sensor is engaged. Washing program time may be prolonged for 10 minutes and the machine still functions perfectly. Time is prolonged for the power failure period. Time is prolonged for extra rinses.

Smeg Washing Machine Manual PDF

Whirlpool Refrigerator ARB-884SGYS Electric Diagram

HVAC Solution