Tag: AC Compressor Capacitor mfd Power and Oil Charge details

Resistance Color Code Value Chart 1 Ω to 10MΩ

Resistance Color Code Value 3 Ring resistance color code Chart Value From 1Ω to 10MΩ. Value 1Ω to 9.1Ω : 3rd Ring is Gold Blank Cell is Color White HVAC and RAC Learn platform You  can Also Subscribe on YouTube  You can also Like on Facebook Page Also read Article in English , Urdu , Hindi

Types of Expansion Valve and his Work

 Types of Expansion Valve: Capillary Tube Automatic Expansion Valve Electronic Expansion Valve Hand Expansion Valve Thermostatic Expansion Valve Image of Expansion Valve : In English Work and Use Of Expansion Valve: This is Important Part Air Conditioner. Expansion Valve Work is that Convert Gas high Pressure to low Pressure. This Valve Adjust where Condenser End

Why Comes Ice on Evaporator and how this solve Fault

Why Comes Ice on Evaporator and how this solve Fault Sometimes Ice comes on evaporator of Window AC when Ice comes on windows AC then AC cooling doesn’t do well. There are many reasons why ice can come to Evaporator. One of which is this. Window AC have one Fan which work for Evaporator and

Indoor and Outdoor both Not Turn ON Solve faults |Fully4world

Indoor and Outdoor both Not Turn ON Solve faults Sometimes your indoor and outdoor both are not work but main power is ON. when we face this problem then we should check Transformer of his PCB kit If his Transformer is OK then check his Fuse. Mostly comes faults when indoor and outdoor unit not

Mostly Faults Comes in Indoor Unit | Fully4world

Mostly Faults Comes in Indoor Unit We face some faults mostly in Indoor unit. we can easily solve this faults. Ice on Evaporator : if we see Ice on Evaporator then we should service AC . If AC is already serviced then check his blower motor speed if his speed is low then we show

AC Compressor wiring burn and installed new wires

AC Compressor wiring burn and installed new wires Sometimes our AC’s every thing ON but do not Cooling Outdoor fan running but Outdoor compressor not running sometimes our compressor burn but sometimes our Compressor wiring burn And the compressor survives. in this Condition that our wiring burn we should take off the old wires new

Indoor air throw low Reasons and Solve Problems

Indoor air throw low Reasons and Solve Problems If our AC’s indoor air throw is low Then the ice comes on the suction pipe. Indoor air throw low have many reasons.  If our AC need Service (Evaporator is dirty) If Blower is dirty If Blower motor is damaged If Blower motor capacitor is damaged Air