Q and A RAC / HVAC |Compressor, Capacitor, Suction Ice, Overload AC ?

Q & A in Urdu and Hindi Q # 1: AC k uper jitny ampere likhy hoty ha agar us sy zyada ampere ly to kya masla ho sakta ha? Ans : Agar AC service hony wala ho ya Gas zayda dal di jay ya Compressor ka Capacitor weak ho to AC zayda Ampere ly … Read more

Why Comes Ice on Evaporator and how this solve Fault

Why Comes Ice on Evaporator and how this solve Fault Sometimes Ice comes on evaporator of Window AC when Ice comes on windows AC then AC cooling doesn’t do well. There are many reasons why ice can come to Evaporator. One of which is this. Window AC have one Fan which work for Evaporator and … Read more

AC Compressor wiring burn and installed new wires

AC Compressor wiring burn and installed new wires Sometimes our AC’s every thing ON but do not Cooling Outdoor fan running but Outdoor compressor not running sometimes our compressor burn but sometimes our Compressor wiring burn And the compressor survives. in this Condition that our wiring burn we should take off the old wires new … Read more

Indoor air throw low Reasons and Solve Problems

Indoor air throw low Reasons and Solve Problems If our AC’s indoor air throw is low Then the ice comes on the suction pipe. Indoor air throw low have many reasons.  If our AC need Service (Evaporator is dirty) If Blower is dirty If Blower motor is damaged If Blower motor capacitor is damaged Air … Read more

Best way to stop leakage in air conditioner

Stop leakage in air conditioner Sometime our AC unit Leak again and again, and this leak is very small. when we face this problem then what we should do. we should open the cover of indoor and outdoor and we should apply chemical on his copper coils. Name of chemical : lacquer spray Epoxy This … Read more

How to set timer on/off in Air conditioner|Easy to use timer AC

Timer on/off in Air conditioner Everyone can see timer button in ac remote, some People know his feature and some People don’t know what is this and how to use this. Function : When we sleep at night and our AC is in running, But when we need to turn off the AC, then we … Read more

AC gets more ampere and trip with heat

Compressor gets more ampere and trip with heat Sometimes our AC takes more amperes and compressor gets hotter and compressor gets trip many people face this problem. This problem comes up when our voltages are not full and when our AC’s outdoor fan capacitor weak or Compressor Capacitor weak. If our voltages are full then … Read more

Compressor over heat & Tripping problem|2019

Compressor over heat Sometimes our Compressor gets trip or gets over heat but our every thing is OK. Some of which are this Voltage Low Problem Over gas Charge Capacitor weak Outdoor Unit to be in the sun But i faced new problem compressor triping. When carbon comes to the Rotary ( common running stating ) … Read more

Long piping effect AC & How much gas needed

Long piping effect AC & How much gas needed In many places we have to install long pipe. If we are Installing a AC and we need long pipe connection, 70ft to 80ft. So our AC will take more amperes. Normal pipe we use for best cooling is 10ft but we can use 20ft to … Read more

Fan blower problems solve|Problems coming from this issue

Fan blower problems solve If there is noise coming from our Indoor Blower motor, This problem comes up when indoor blower attach with indoor body, So this can lead to many issues Problems coming from this issue Cooling will reduce Ice coming on the evaporator Blower motor to be damaged we should open indoor Cover … Read more