Tag: Air conditioner Error codes troubleshooting list errors E2

Haier AC error code list

we face sometimes error code in AC service or repairing in this post you can see Haier AC error code list in jpg and you can solve fault after see this error code list  Haier Error Code list You should read it : Gree error code list jpg changhong ruba ac error code list Daikin

Gree error code list jpg

we face sometimes error code in AC service or repairing in this post you can see Gree error code list jpg and you can solve fault after see this error code list  Error code list of Gree You should read it : changhong ruba ac error code list Daikin Ac error code list | Error

Mostly Coming Error code in Air Conditioner

Coming Error code in Air Conditioner Error Code List : E1 Compressor High pressure Protection E2 Indoor anti-freeze Protection E3 Compressor Low pressure Protection , Refrigerant lack Protection and refrigerant collating mode E4 Compressor High discharge temperature Protection E6 Communication error E8 Indoor fan motor error E9 Full water protection HVAC and RAC Learn platform

Capacitor Testing Meter Buy Online

Capacitor Testing Meter 1. 100% Brand New and never used, please bid with confidence.2. LCD Screen Display3. With battery and probe4. Model: XC6013L5. Each parts is tested before shipping to be 100% working. How to Use watch Video

E4, E5, E6 Error Code in non Inverter AC Solve

E4, E5, E6 Error Code in non Inverter AC Solve Some Non Inverter AC don’t  show error Code but some show error in LED. When we see E4 error in non Inverter then we should check his indoor Blower Motor we should disconnect wire his blower motor from PCB and again Connect and check that

Outdoor Fan Motor 4 Wires Connection and Trace

Outdoor Fan Motor 4 Wires Connection and Trace If outdoor fan motor have 4 wire then how we can trace that which is common running starting which is 4th wire. we can easily find with multi-meter, multi-meter set on Continuity (Beep) and in this 4 wires 2 wires work same this 2 wires attach with

Crrier DC inverter Error Code list

The error message is shown at the OUTDOOR UNIT CONTROLLER as following table: Outdoor Temperature Sensor Failure Ambient temperature sensor E0 Inlet coil temperature sensor E1 Suction temperature sensor E2 Mid coil temperature sensor E3 DLT Digital Compressor sensor E4 Outdoor Status Error Communication error between indoor & outdoor unit controllers [E High pressure status

Galanz AC Error Code

F6 PG motor faults F7 Indoor TEMP sensor faults F8 Indoor coil pipe TEMP sensor faults F9 Outdoor coil pipe TEMP sensor faults Trouble Solve Methods E1 The trouble of indoor unit room temperature sensor. E2 The trouble of unit pipe temperature sensor. indoor E3 The trouble of PG motor E5 The trouble of bad

Acson AC Error Codes and Troubleshooting

The code indication changes as shown below, and notifies with a long beep. E1 Outdoor Pcb Error E3 High Pressure Protection E4 Low Pressure Protection E5 Compressor Motor Lock/Compressor Overloaded E6 Compressor Start-up Error E7 Outdoor Dc Fan Motor Lock E8 Ac Input Over Current E9 Exv Errorea 4 Way Valve Error F3 Discharge Pipe

Carrier Indoor Unit Error Code

E0 Indoor unit EEPROM parameter error E1 Indoor / outdoor units communication error E3 Indoor fan speed has been out of control E4 Indoor room temperature sensor T1 open circuit or shortcircuit E5 Evaporator coil temperature sensor T2 open circuit or short circuit EC Refrigerant Leakage Detection F1 Outdoor ambient temperature sensor T4 open circuit