Compressor will dead When there is water in the compressor

In English Compressor will dead if water goes in compressor Sometimes we wash Refrigerator with knife and refrigerator gets leak with The tip of the knife Then we should Turn OFF our Refrigerator So that the water does not go into the compressor If the water goes into the compressor, the compressor will be damaged

How to Check rotary Compressor that Damage or not

How to Check rotary Compressor If we have a rotary compressor and we don’t know it’s bad or not. we should check his short that this compressor is short or not. Multimeter set on buzzer and one wire of multimeter attach with compressor body and second wire of multimeter attach with compressor terminal one by

AC gets more ampere and trip with heat

Compressor gets more ampere and trip with heat Sometimes our AC takes more amperes and compressor gets hotter and compressor gets trip many people face this problem. This problem comes up when our voltages are not full and when our AC’s outdoor fan capacitor weak or Compressor Capacitor weak. If our voltages are full then

Compressor over heat & Tripping problem|2019

Compressor over heat Sometimes our Compressor gets trip or gets over heat but our every thing is OK. Some of which are this Voltage Low Problem Over gas Charge Capacitor weak Outdoor Unit to be in the sun But i faced new problem compressor triping. When carbon comes to the Rotary ( common running stating )

How Check Rotary Compressor is damage or not

How Check Rotary Compressor is damage or not we can also check with Multi meter that our Compressor is damage or not. we should always check his terminal continuity value. How to check common Running Starting If any point not show continuity value on meter then compressor is damage. if Compressor running with high ampere

AC Compressor Triping top Reason | Outdoor Triping

Compressor Triping top Reason Mostly Outdoor Units trip Due to heat up, we do Discuss some top reason of Outdoor Compressor Triping. If our Coil sensor is damage then this problem comes in PCB that our sensor is damage, But by this problem our all Outdoor closes, his fan and his Compressor. If our Compressor

Phase and Neutral of Compressor problem

Phase and Neutral of Compressor problem Some people say that Comman point of compressor is phase and running point of compressor is neutral and Some people say that Comman point of compressor is neutral and running point of compressor is phase. But don’t worry you can adjust Neutral and Phase wire anywhere your compressor will