Tag: ac error code f1

Mostly Coming Error code in Air Conditioner

Coming Error code in Air Conditioner Error Code List : E1 Compressor High pressure Protection E2 Indoor anti-freeze Protection E3 Compressor Low pressure Protection , Refrigerant lack Protection and refrigerant collating mode E4 Compressor High discharge temperature Protection E6 Communication error E8 Indoor fan motor error E9 Full water protection HVAC and RAC Learn platform

Types of Expansion Valve and his Work

 Types of Expansion Valve: Capillary Tube Automatic Expansion Valve Electronic Expansion Valve Hand Expansion Valve Thermostatic Expansion Valve Image of Expansion Valve : In English Work and Use Of Expansion Valve: This is Important Part Air Conditioner. Expansion Valve Work is that Convert Gas high Pressure to low Pressure. This Valve Adjust where Condenser End

Changhong Ruba DC inverter Error Code

Changhong Ruba DC inverter Error Code List Read and Fix Problems  F1 Indoor Room Temperature Sensor Fault F2 Outdoor Discharge Temperature Sensor Fault F3 Indoor Coil Temperature Sensor Fault F4 Indoor Fan Motor Faukt F4 Outdoor Section Line Temperature Sensor Fault F5 Gas Pressure High or Low F6 Communication Fault Between indoor to Outdoor HVAC

How to repair Gauge| Gauge Needle

How to repair Gauge Sometimes your Gauge needle is back and forth from 0 PSI then how we can repair and adjust Needle at 0 PSI we can easily repair this fault. we should open his Blue or Red Cover and after this open his Plastic glass rotate the plastic glass anti clockwise So its

Why Comes Ice on Evaporator and how this solve Fault

Why Comes Ice on Evaporator and how this solve Fault Sometimes Ice comes on evaporator of Window AC when Ice comes on windows AC then AC cooling doesn’t do well. There are many reasons why ice can come to Evaporator. One of which is this. Window AC have one Fan which work for Evaporator and

Indoor and Outdoor both Not Turn ON Solve faults |Fully4world

Indoor and Outdoor both Not Turn ON Solve faults Sometimes your indoor and outdoor both are not work but main power is ON. when we face this problem then we should check Transformer of his PCB kit If his Transformer is OK then check his Fuse. Mostly comes faults when indoor and outdoor unit not

Mostly Faults Comes in Indoor Unit | Fully4world

Mostly Faults Comes in Indoor Unit We face some faults mostly in Indoor unit. we can easily solve this faults. Ice on Evaporator : if we see Ice on Evaporator then we should service AC . If AC is already serviced then check his blower motor speed if his speed is low then we show

AC Compressor wiring burn and installed new wires

AC Compressor wiring burn and installed new wires Sometimes our AC’s every thing ON but do not Cooling Outdoor fan running but Outdoor compressor not running sometimes our compressor burn but sometimes our Compressor wiring burn And the compressor survives. in this Condition that our wiring burn we should take off the old wires new