Tag: ac error code

Changhong Ruba DC inverter Error Code

Changhong Ruba DC inverter Error Code List Read and Fix Problems  F1 Indoor Room Temperature Sensor Fault F2 Outdoor Discharge Temperature Sensor Fault F3 Indoor Coil Temperature Sensor Fault F4 Indoor Fan Motor Faukt F4 Outdoor Section Line Temperature Sensor Fault F5 Gas Pressure High or Low F6 Communication Fault Between indoor to Outdoor HVAC

Why Comes Ice on Evaporator and how this solve Fault

Why Comes Ice on Evaporator and how this solve Fault Sometimes Ice comes on evaporator of Window AC when Ice comes on windows AC then AC cooling doesn’t do well. There are many reasons why ice can come to Evaporator. One of which is this. Window AC have one Fan which work for Evaporator and

AC Compressor wiring burn and installed new wires

AC Compressor wiring burn and installed new wires Sometimes our AC’s every thing ON but do not Cooling Outdoor fan running but Outdoor compressor not running sometimes our compressor burn but sometimes our Compressor wiring burn And the compressor survives. in this Condition that our wiring burn we should take off the old wires new

Indoor air throw low Reasons and Solve Problems

Indoor air throw low Reasons and Solve Problems If our AC’s indoor air throw is low Then the ice comes on the suction pipe. Indoor air throw low have many reasons.  If our AC need Service (Evaporator is dirty) If Blower is dirty If Blower motor is damaged If Blower motor capacitor is damaged Air

E4, E5, E6 Error Code in non Inverter AC Solve

E4, E5, E6 Error Code in non Inverter AC Solve Some Non Inverter AC don’t  show error Code but some show error in LED. When we see E4 error in non Inverter then we should check his indoor Blower Motor we should disconnect wire his blower motor from PCB and again Connect and check that

Air Conditioner water drop in the room (Tips&Tricks)

Air Conditioner water drop in the room Sometime after AC service water drops fall in the Room. We have to face this problem several times. Service the AC on the wall can cause this problem when we Service the AC on the wall So not all AC parts are cleaned thoroughly.  Indoor have three or

Crrier DC inverter Error Code list

The error message is shown at the OUTDOOR UNIT CONTROLLER as following table: Outdoor Temperature Sensor Failure Ambient temperature sensor E0 Inlet coil temperature sensor E1 Suction temperature sensor E2 Mid coil temperature sensor E3 DLT Digital Compressor sensor E4 Outdoor Status Error Communication error between indoor & outdoor unit controllers [E High pressure status

F0 Error in Gree Inverter AC

F0 Error in Gree Inverter F0 error code in Gree Inverter AC. Each company’s AC Error code is different. But We will talk F0 error code in Gree Inverter AC. Due to gas low F0 error come in Gree Inverter. When the gas is completed, this error will end. 3,994 total views, no views today

Gree To 50 Error Code

E1 Refrigerant system high pressure protection E2 Anti-freezing protection E4 Compressor exhaust high temperature protection E5 AC over-current protection E6 Communication failure between indoor and outdoor Unit E8 Anti- high temperature protection H6 No feedback of indoor fan motor C5 Jumper cap malfunction protection F1 Indoor ambient sensor open or short circuit F2 Indoor tube