Rotary Compressor Back Pressure fix problem

In English Rotary Compressor Back Pressure fix problem Sometimes Rotary Compressor hit Back Pressure (Reverse Pressure). and then Our Compressor will damage and AC will not Cooling.  How we can Solve this? We should Check his by Remove the oil from the compressor. The compressor has to be reversed to extract the oil and stay

How to check Inverter Refrigerator Compressor

In English Check Inverter Refrigerator Compressor: If we working anywhere of inverter Refrigerator Or inverter AC and we want check his Compressor that his Compressor is OK or not, So we should have a PCB kit Because if we turn ON this compressor Direct 220V Volt then this compressor will burned. So we should have

Refrigerator Compressor Trip again and again

Refrigerator Compressor Trip Why and How to solve Refrigerator Compressor Trip : Sometimes we Turn ON Refrigerator But the refrigerator doesn’t cool anything If we keep anything in the refrigerator, it gets worse.  How to Solve this Problem We should Check his Thermostat sometimes his thermostat goes bad and does not work properly. We should Start

How to Check rotary Compressor that Damage or not

How to Check rotary Compressor If we have a rotary compressor and we don’t know it’s bad or not. we should check his short that this compressor is short or not. Multimeter set on buzzer and one wire of multimeter attach with compressor body and second wire of multimeter attach with compressor terminal one by

AC gets more ampere and trip with heat

Compressor gets more ampere and trip with heat Sometimes our AC takes more amperes and compressor gets hotter and compressor gets trip many people face this problem. This problem comes up when our voltages are not full and when our AC’s outdoor fan capacitor weak or Compressor Capacitor weak. If our voltages are full then

Compressor over heat & Tripping problem|2019

Compressor over heat Sometimes our Compressor gets trip or gets over heat but our every thing is OK. Some of which are this Voltage Low Problem Over gas Charge Capacitor weak Outdoor Unit to be in the sun But i faced new problem compressor triping. When carbon comes to the Rotary ( common running stating )

How Check Rotary Compressor is damage or not

How Check Rotary Compressor is damage or not we can also check with Multi meter that our Compressor is damage or not. we should always check his terminal continuity value. How to check common Running Starting If any point not show continuity value on meter then compressor is damage. if Compressor running with high ampere

AC Compressor Triping top Reason | Outdoor Triping

Compressor Triping top Reason Mostly Outdoor Units trip Due to heat up, we do Discuss some top reason of Outdoor Compressor Triping. If our Coil sensor is damage then this problem comes in PCB that our sensor is damage, But by this problem our all Outdoor closes, his fan and his Compressor. If our Compressor