AC piping ice Trace Fault | Fully4world

Tag: AC piping ice Trace Fault

AC Compressor wiring burn and installed new wires

AC Compressor wiring burn and installed new wires Sometimes our AC’s every thing ON but do not Cooling Outdoor fan running but Outdoor compressor not running sometimes our compressor burn but sometimes our Compressor wiring burn And the compressor survives. in this Condition that our wiring burn we should take off the old wires new

Indoor air throw low Reasons and Solve Problems

Indoor air throw low Reasons and Solve Problems If our AC’s indoor air throw is low Then the ice comes on the suction pipe. Indoor air throw low have many reasons.  If our AC need Service (Evaporator is dirty) If Blower is dirty If Blower motor is damaged If Blower motor capacitor is damaged Air

E4, E5, E6 Error Code in non Inverter AC Solve

E4, E5, E6 Error Code in non Inverter AC Solve Some Non Inverter AC don’t  show error Code but some show error in LED. When we see E4 error in non Inverter then we should check his indoor Blower Motor we should disconnect wire his blower motor from PCB and again Connect and check that

Gas Store, R600, Long Pipe, Question and Answer ?

Q1. How much is R600 Gas Running Pressure and Standing Pressure? Ans. R600 Running  Pressure is 0 Psi to 2 Psi and Standing Pressure is 40 Psi to 50 Psi. Q2. What we can Attach 2 Ton indoor Unit with 1.5 Ton Outdoor unit ? Ans. Yes we can Attach 2 Ton indoor with 1.5

How to Trace fault with Gas Pressure & Line Gauge

How to Trace fault with Gas Pressure & Line Gauge We can Trace some fault with running and standing pressure. when AC is turn ON then the pressure that appears on the gauge is Running Pressure and when AC is turn OFF then the pressure that appears on the gauge is Standing Pressure. R22 Normal

Light blink error Solve problem|Error code

Light blink error Old model of AC light blink error, indoor unit is ON but power supply not reach outdoor. When we see this error then we should change his room temperature and coil sensor if his sensor is OK then remove his sensor Jack and re apply if not solve this problem then his

How to open easy rust screws & Bolts

Open rust able screws & Bolts Sometimes rust gets on our nut or Screw, and it doesn’t open easily, screw driver and key are happening slipped. we can open it with some ways. By heating it By using WD40 By grip plier By Heating : we can heat it by gas welding plant but be

AC gets more ampere and trip with heat

Compressor gets more ampere and trip with heat Sometimes our AC takes more amperes and compressor gets hotter and compressor gets trip many people face this problem. This problem comes up when our voltages are not full and when our AC’s outdoor fan capacitor weak or Compressor Capacitor weak. If our voltages are full then