Error code | Fully4world

Tag: Error code

E4, E5, E6 Error Code in non Inverter AC Solve

E4, E5, E6 Error Code in non Inverter AC Solve Some Non Inverter AC don’t  show error Code but some show error in LED. When we see E4 error in non Inverter then we should check his indoor Blower Motor we should disconnect wire his blower motor from PCB and again Connect and check that

Light blink error Solve problem|Error code

Light blink error Old model of AC light blink error, indoor unit is ON but power supply not reach outdoor. When we see this error then we should change his room temperature and coil sensor if his sensor is OK then remove his sensor Jack and re apply if not solve this problem then his

Outdoor Fan Motor 4 Wires Connection and Trace

Outdoor Fan Motor 4 Wires Connection and Trace If outdoor fan motor have 4 wire then how we can trace that which is common running starting which is 4th wire. we can easily find with multi-meter, multi-meter set on Continuity (Beep) and in this 4 wires 2 wires work same this 2 wires attach with

Air Conditioner water drop in the room (Tips&Tricks)

Air Conditioner water drop in the room Sometime after AC service water drops fall in the Room. We have to face this problem several times. Service the AC on the wall can cause this problem when we Service the AC on the wall So not all AC parts are cleaned thoroughly.  Indoor have three or

AC Compressor Triping top Reason | Outdoor Triping

Compressor Triping top Reason Mostly Outdoor Units trip Due to heat up, we do Discuss some top reason of Outdoor Compressor Triping. If our Coil sensor is damage then this problem comes in PCB that our sensor is damage, But by this problem our all Outdoor closes, his fan and his Compressor. If our Compressor

Crrier DC inverter Error Code list

The error message is shown at the OUTDOOR UNIT CONTROLLER as following table: Outdoor Temperature Sensor Failure Ambient temperature sensor E0 Inlet coil temperature sensor E1 Suction temperature sensor E2 Mid coil temperature sensor E3 DLT Digital Compressor sensor E4 Outdoor Status Error Communication error between indoor & outdoor unit controllers [E High pressure status

F0 Error in Gree Inverter AC

F0 Error in Gree Inverter F0 error code in Gree Inverter AC. Each company’s AC Error code is different. But We will talk F0 error code in Gree Inverter AC. Due to gas low F0 error come in Gree Inverter. When the gas is completed, this error will end. 1,840 total views, 1 views today

Galanz AC Error Code

F6 PG motor faults F7 Indoor TEMP sensor faults F8 Indoor coil pipe TEMP sensor faults F9 Outdoor coil pipe TEMP sensor faults Trouble Solve Methods E1 The trouble of indoor unit room temperature sensor. E2 The trouble of unit pipe temperature sensor. indoor E3 The trouble of PG motor E5 The trouble of bad

Acson AC Error Codes and Troubleshooting

The code indication changes as shown below, and notifies with a long beep. E1 Outdoor Pcb Error E3 High Pressure Protection E4 Low Pressure Protection E5 Compressor Motor Lock/Compressor Overloaded E6 Compressor Start-up Error E7 Outdoor Dc Fan Motor Lock E8 Ac Input Over Current E9 Exv Errorea 4 Way Valve Error F3 Discharge Pipe

DC Inverter E1 Error Solved [In Hindi/Urdu and English]

In Urdu In English We found E1 Error Orient DC Inverter. The E1 Error is an Out Door Temperature  sensor or indoor Temperature sensor. And then i Changed Both Sensors But after all this change, the problem was not resolved. when i open the PCB kit from Out Door,  Then I see that the part