Changhong Ruba DC inverter Error Code List Read and Fix Problems F1 Indoor Room Temperature Sensor Fault F2 Outdoor Discharge Temperature Sensor Fault F3 Indoor Coil Temperature Sensor Fault F4 Indoor Fan Motor Faukt F4 Outdoor Section Line Temperature Sensor Fault F5 Gas Pressure High or Low F6 Communication Fault Between indoor to Outdoor HVAC
E4, E5, E6 Error Code in non Inverter AC Solve Some Non Inverter AC don’t show error Code but some show error in LED. When we see E4 error in non Inverter then we should check his indoor Blower Motor we should disconnect wire his blower motor from PCB and again Connect and check that
Light blink error Old model of AC light blink error, indoor unit is ON but power supply not reach outdoor. When we see this error then we should change his room temperature and coil sensor if his sensor is OK then remove his sensor Jack and re apply if not solve this problem then his
Outdoor Fan Motor 4 Wires Connection and Trace If outdoor fan motor have 4 wire then how we can trace that which is common running starting which is 4th wire. we can easily find with multi-meter, multi-meter set on Continuity (Beep) and in this 4 wires 2 wires work same this 2 wires attach with
Air Conditioner water drop in the room Sometime after AC service water drops fall in the Room. We have to face this problem several times. Service the AC on the wall can cause this problem when we Service the AC on the wall So not all AC parts are cleaned thoroughly. Indoor have three or
Compressor Triping top Reason Mostly Outdoor Units trip Due to heat up, we do Discuss some top reason of Outdoor Compressor Triping. If our Coil sensor is damage then this problem comes in PCB that our sensor is damage, But by this problem our all Outdoor closes, his fan and his Compressor. If our Compressor
The error message is shown at the OUTDOOR UNIT CONTROLLER as following table: Outdoor Temperature Sensor Failure Ambient temperature sensor E0 Inlet coil temperature sensor E1 Suction temperature sensor E2 Mid coil temperature sensor E3 DLT Digital Compressor sensor E4 Outdoor Status Error Communication error between indoor & outdoor unit controllers [E High pressure status
F0 Error in Gree Inverter F0 error code in Gree Inverter AC. Each company’s AC Error code is different. But We will talk F0 error code in Gree Inverter AC. Due to gas low F0 error come in Gree Inverter. When the gas is completed, this error will end. 3,994 total views, no views today
F6 PG motor faults F7 Indoor TEMP sensor faults F8 Indoor coil pipe TEMP sensor faults F9 Outdoor coil pipe TEMP sensor faults Trouble Solve Methods E1 The trouble of indoor unit room temperature sensor. E2 The trouble of unit pipe temperature sensor. indoor E3 The trouble of PG motor E5 The trouble of bad
The code indication changes as shown below, and notifies with a long beep. E1 Outdoor Pcb Error E3 High Pressure Protection E4 Low Pressure Protection E5 Compressor Motor Lock/Compressor Overloaded E6 Compressor Start-up Error E7 Outdoor Dc Fan Motor Lock E8 Ac Input Over Current E9 Exv Errorea 4 Way Valve Error F3 Discharge Pipe
This website uses cookies to improve your experience. We'll assume you're ok with this, but you can opt-out if you wish. Cookie settingsACCEPT
Privacy & Cookies Policy
Privacy Overview
This website uses cookies to improve your experience while you navigate through the website. Out of these cookies, the cookies that are categorized as necessary are stored on your browser as they are essential for the working of basic functionalities of the website. We also use third-party cookies that help us analyze and understand how you use this website. These cookies will be stored in your browser only with your consent. You also have the option to opt-out of these cookies. But opting out of some of these cookies may have an effect on your browsing experience.
This website uses cookies to improve your experience while you navigate through the website. Out of these cookies, the cookies that are categorized as necessary are stored on your browser as they are essential for the working of basic functionalities of the website. We also use third-party cookies that help us analyze and understand how you use this website. These cookies will be stored in your browser only with your consent. You also have the option to opt-out of these cookies. But opting out of some of these cookies may have an effect on your browsing experience.
Necessary cookies are absolutely essential for the website to function properly. This category only includes cookies that ensures basic functionalities and security features of the website. These cookies do not store any personal information.
Any cookies that may not be particularly necessary for the website to function and is used specifically to collect user personal data via analytics, ads, other embedded contents are termed as non-necessary cookies. It is mandatory to procure user consent prior to running these cookies on your website.